亚洲爆乳大丰满无码专区_久久久精品午夜免费不卡_国产不卡无码不卡无码不卡无码_亚洲AⅤ无码一区二区三区_国产成人久久AV免费高潮

北京恒遠(yuǎn)安諾科技有限公司

產(chǎn)品中心/ products

您的位置:首頁  -  產(chǎn)品中心  -  電工校準(zhǔn)儀器  -  其他校準(zhǔn)儀器  -  電壓電流校正器

電壓電流校正器

  • 產(chǎn)品型號(hào):Model 828
  • 更新時(shí)間:2024-06-20

簡要描述:Model 828電壓電流校正器

產(chǎn)品詳情

FEATURES

AC/DC Output                                          
Wide Range - 1 Millivolt to 1100 Volts,         
      1 Microampere to 5 Amperes
High Accuracy
Ease of Operation
High Stability
Direct Reading Percent Deviation of
      Output Control
High Burden and Compliance Ratings
Short Circuit and Overburden Protection
Continuous Resolution Run-up for Analog Meter Friction Testing
Compact Size for Ease of Portability and Minimum Bench Space
      Requirements
Rapid Warm-up

APPLICATIONS

Calibration of: Designed for use in:
    
Analog Panel Meters Production Line Testing
Portable Volt-Amp Multimeters Laboratory Calibration
3 1/2 Digit Panel Meters Field Calibration Service
Transducers Plant Calibration
Recorders  

DESCRIPTION

 

SPECIFICATIONS

OUTPUT SPECIFICATIONS

Voltage Calibrator

Full Scale Ranges:

Four: 1, 10, 100, and 1000 V.
Overrange Limits: 1100 volts on 1000 V range;
200% of full-scale value on all other ranges.
Stability: ?.05%/8 hours; within rated accuracy for 6 months.
Voltage Burden: 5 VA on 1 V range; 10 VA on all other ranges.

Current Calibrator
Full Scale Ranges: Five: 1, 10, and 100 mA; 1 and 10A
Overrange Limits: 5 amps on 10A range; 200% of full-scale value on all other ranges.
Compliance: 1 volt on 10 A range; 5 volts on all other ranges.

ACCURACY

Output Mode Accuracy
Dc Voltage ?0.05% of setting + 0.05% of range)
Ac Voltage ?0.05% of setting + 0. 1 % of range)
Current ?0. 1 % of setting + 0. 1 % of range)

GENERAL

Total Harmonic Distortion Less than 0.3% at full-scale.
  
Ripple (Dc Operation Only) Less than 1 % rms at full-scale with 1 MW load.

Internal Frequency Source
Frequencies: 50, 60, and 400 Hz.
Accuracy: 50 and 400 Hz: 眑 %
60 Hz: ?.5%

External Frequency Input
Frequency Limits: 50 to 440 Hz.
Input Voltage 3 volts maximum

% Deviation Control
Range: ?% of setting, adjustable via front panel control.
Accuracy: 眑 /2 division (0.05%).
   
Warm-Up Time Less than 3 minutes at room temperature.
    
Operating Temperature +18癈 to+28癈 (+65癋 to+82癋) for rated accuracy; the Model 828 may be operated from 癈 to +1 8癈 (+32癋 to +65癋) and +28癈 and +50癈 (+82癋 to +122癋) at derated specifications.

Input Power Requirements
Standard: 115 V Operation: 104 to 127 volts, 47 to 63 Hz, 45 watts
230 V Operation: 207 to 253 volts, 47 to 63 Hz, 45 watts
Optional: 100 V Operation: 90 to 110 volts, 47 to 63 Hz, 45 watts
200 V Operation: 1 80 to 220 volts, 47 to 63 Hz, 45 watts

Dimensions
Height: 1 9 cm (71/2 inches)
Width: 21.6 cm (81/2 inches)
Depth: 33 cm (13 inches)
 
Weight: 25 lbs (11.3 kg)

 

High burden capability is achieved by a rating of 10VA on the higher voltage ranges and a rating of 5VA on the one volt range. Compliance of the current ranges is 5V except for the 10A range where it is 1V.

The percent error of a meter under test may be quickly determined and directly read by use of the Model 828's Percent Error control. Analog meters may be tested for "sticky" movements by use of the run-up mode which allows voltage or current to be smoothly and continuously applied to the meter under test.

The calibrator supplies voltage and current at dc and at internally generated frequencies of 50, 60 and 400 Hz. Low ripple on dc functions and low distortion in ac modes minimizes random error when calibrating digital and rectifier type instruments. It is protected against accidental short circuit or overburdening of the output by internal sense circuitry which removes the output voltage or current if the load ratings are exceeded.

High output stability makes this instrument suitable for use as a constant current or constant voltage source.

The Model 828 Current-Voltage Calibrator   is a compact, self-regulating instrument capable of meeting a high percentage of calibration requirements for laboratory, production line and field use. A minimum number of controls assure ease of operation for all grades of personnel. Output voltage and current are set by fingertip operation of a centrally located digital readout  /selector control. Setting time is less than 1.5 second. Voltage Calibrator output is covered in four ranges: 1V, 10V, 100V and 1000V with * over-range on the three lower ranges and 10% over-range on the 1000V range. Current Calibrator output is supplied in five full-scale ranges of 1, 10, 100mA and 1 and 10A. Over-range is * on all ranges except the 10A range where maximum output is 5A.

在線咨詢

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7